Cpap Machine

Providing you the best range of resmed airsense 10 autoset with humidifier and resmed lumis 150 vpap st with effective & timely delivery.
Request CallBack
  • Resmed Airsense 10 Autoset with Humidifier
  • Resmed Airsense 10 Autoset with Humidifier
Resmed Airsense 10 Autoset with Humidifier
Get Best Quote

Resmed Airsense 10 Autoset with Humidifier

Approx. Price: Rs 70,000 / UnitGet Latest Price
Product Details:
Minimum Order Quantity1 Unit
Usage/ApplicationHospital
Product Specifications

Weight - Machine with Water Chamber: 2.75 lbs (44 oz.)

Dimensions - Machine with Water Chamber: 10.04 in L x 4.57 in W x 5.91 in H

Weight - Standard Chamber: .54 lb

 

Weight - Machine with Side Cover (Without Water Chamber): Approx. 2.452 lbs

Dimensions - Machine with Side Cover (Without Water Chamber): Approx. 8 in L x 4.57 in W x 5.91 in H

Dimensions - Travel Bag: 13.24 in L x 10 in W x 5 in H

Weight - Travel Bag Alone: 1.18 lb

Weight - Machine with Humidifier; Power Supply and Cord; SlimLine Tube; Travel Bag: Approximately 5.1 lbs

Weight - Machine with Humidifier; Power Supply and Cord; OPTIONAL ClimateLineAir Tube; Travel Bag: Approximately 5.25 lbs

Sound Level: 26.6 dBA

Water Chamber Capacity: 380 mL

Weight - 90W Power Supply, Cord and Plug: 1.29 lb

Dimensions - 90W Power Supply Only (Not including Cord or Plug): 5 1/2 in x 1 7/8 in x 1 1/4 in

AC Input Range - 90W Power Supply: 100 - 240V, 50 - 60Hz, 1.0 - 1.5A, Class II

DC Output - 90 W Power Supply: 24V --- 3.75A

Typical Power Consumption: 53W (57VA)

Peak Power Consumption: 104W (108VA)

Operating Pressure: 4 - 20 cm H2O (0.2 cm increments)

Length - SlimLine Tubing: 6 feet

Materials - SlimLine Tubing: Flexible Plastic

Materials - Water Chamber: Injection Molded Plastic, Stainless Steel, Silicone Seal

Materials - Standard Filter: Polyester non-woven fiber

Temperature Range - Optional ClimateLineAir™ Heated Tube: 60 - 80° F (16 - 30° C)

Operating Temperature: 41° F - 95° F (5° C - 35° C)

Storage and Transport Temperature: -4° F - 140° F (-20° C - 60° C)

Operating Humidity: 10% - 95% Relative Humidity, non-condensing

Storage and Transport Humidity: 5% - 95% relative Humidity, non-condensing

Operating Altitude: Sea Level - 8500 Feet (2,591 M); Air pressure range 1013 hPa - 738 hPa

Maximum Temperature - Heating Plate: 154° F (68° C)

Maximum Temperature - Cut Out: 165° F (74° C)

Maximum Gas Temperature: Less than or Equal to 106° F (? 41° C)

IEC 60601-1:2005 Classification: Class II (Double Insulation), Type BF, Ingress protection IP22

Machine Warranty: 2 Years

Patient Weight: Greater than 66 lbs

Cleaning Instructions

The chamber should be taken apart and hand washed weekly using warm water and a mild detergent. It should be rinsed well and allowed to air dry out of direct sunlight before reassembling. The chamber should not be washed in a dishwasher or washing machine. The SlimLine hose should be washed in the same manner and allowed to completely dry out of direct sunlight before reattaching to the machine and mask.

Required Settings: This machine does not have required settings.

Unless directed otherwise,

  • Mode: AutoSet
  • Minimum Pressure: 4 cm H2O
  • Maximum Pressure: 20 cm H2O
  • Ramp: Auto
  • Start Pressure: 4 cm H2O
  • Humidity Level: 4
  • Mask Type: Pillows
  • EPR: Off
  • SmartStart: Off
  • Tube Type: Slimline
  • Antibacterial Filter: No

Yes! I am Interested
Request CallBack
Resmed Lumis 150 VPAP ST
Get Best Quote

Resmed Lumis 150 VPAP ST

Approx. Price: Rs 92,000 / UnitGet Latest Price
Product Details:
BrandResmed
ModesCPAP
Usage/ApplicationCopd
ntelligentAir is a collection of ResMed technologies that can tailor therapy to individual breathing needs:
iVAPS learns each patient’s unique alveolar ventilation, sets appropriate targets, then provides smooth pressure support to suit.intelligent Backup Rate (iBR)* gives patients maximum opportunity to trigger the ventilator. Staying out of the way until needed, iBR adds backup breaths to comfortably bring patients back to target. *Available in iVAPS and ST modes.AutoEPAP** maintains upper airway patency by auto-adjusting the expiratory pressure in response to partial and full obstructions. **Available in iVAPS mode.Vsync provides excellent patient–ventilator synchrony, even in the presence of significant leak.TiControl™ lets you set min and max limits on either side of the patient’s ideal inspiratory time to encourage spontaneous breathing.Trigger and cycle helps you optimise settings according to the patient’s condition, using five trigger and cycle sensitivity levels.QuickNav for low-touch therapy adjustment. By simply double-clicking the home button on the device, you can toggle between the Settings and Monitoring screens to change and check settings quickly and easily.Climate Control Auto for automatic humidification. When used with a HumidAir™ heated humidifier and ClimateLineAir™ heated tube, Lumis delivers humidification automatically – no settings to change and no complicated menus to navigate.Ramp and Ramp Down for extra comfort. Lumis offers both Ramp and Ramp Down features to help patients ease into and out of each therapy session.ResScan software for advanced clinical insights. ResScan enables you to download your patients’ therapy data, change ventilator settings, and gain insight into their therapy progress across a number of metrics (including AHI, leak and pressure). High-resolution data (at 25 Hz) is also available for breath-by-breath analysis and even greater insight.

Yes! I am Interested